ADR-0009: Reactive power, voltage control, shunts and fixed transfers complete the power-flow network; power-flow inputs are ignored where no power flow runs

  • Status: accepted
  • Date: 2026-10-24

Context

ADR-0008 made the AC network canonical for an active-power flow: voltage levels, line and transformer impedances, one fixed active dispatch per injection, a slack. That is enough to see angles, active flows and the voltage sag they cause, but not what a distribution planner checks next: reactive power, which decides voltage magnitudes, voltage-controlled generation, compensation at a node, and controlled DC transfers between AC buses. PyPSA solves all of these in pf() (q_set on loads, generators and storage units, control: PV with the bus v_mag_pu_set, ShuntImpedance, p_set on a Link between AC buses, line b/g, transformer phase_shift). Reaching them through native.pypsa works for constants only, is unvalidated, and cannot add a component MEME does not emit.

The same decision has to settle what the other targets do with these inputs. ADR-0008 rejected dispatch in every optimization mode and merely warned about electrical parameters. The consumer's workflow is one model sent twice, to a planning target and to the power flow, and a rejection on the planning side forces a second, stripped copy of the payload for no gain: an optimization decides dispatch and never reads reactive set-points, so ignoring them changes nothing in its result.

Decision

The power-flow network gains four groups of fields, each on the entity it physically belongs to, each read only in mode power_flow, each mapped onto one PyPSA attribute:

  • Technology electrical (overridable per node): reactive_dispatch (MVAr per timestep, q_set) or power_factor with optional leading (the emitter derives Q from the active set-point in the component's own direction: a load consumes, a generator supplies), control pq or pv (supply only; pv holds its bus at voltage_setpoint), and voltage_setpoint (pu) for pv generators and the slack. Conversion technologies carry no reactive fields: a PyPSA Link transfers active power only.
  • Node electrical.shunt (g, b in siemens): one ShuntImpedance at the node's AC bus.
  • Transmission dispatch (MW from from to to): a controlled transfer on an arc without impedance, PyPSA's model of an HVDC link. An electricity arc in a power flow needs either electrical or dispatch, never both: a line's flow is a result.
  • Branch refinements in transmission.electrical: b and g (line shunt admittance), phase_shift (transformer, degrees), and r_per_length/x_per_length as the alternative to r/x, multiplied by distance at emission. Cable-type catalogues stay outside MEME: the consumer resolves the type, MEME takes values.

Every power-flow input — dispatch on technologies and arcs, the electrical blocks on nodes, arcs and technologies — is ignored with one warning wherever no power flow runs: on Calliope and AdOpT-NET0, which have no such concept, and on PyPSA in every optimization mode. The warning names the fields and the entities, so nothing is dropped silently, and the planning payload and the power-flow payload may be the same document. This supersedes the rejection of dispatch in optimization modes that ADR-0008 introduced. Mode power_flow itself stays rejected on targets without the capability: a run cannot be ignored.

Inside a power flow the gates tighten instead: a reactive set-point and a power factor are mutually exclusive; pv control is for supply technologies; a voltage_setpoint needs pv control or the slack; all set-points at one bus must agree; method: linear reports that reactive quantities and voltage control play no part in a DC solve.

Consequences

  • A planner can hold voltages, see reactive flows and compensation effects, and model HVDC ties, all through canonical fields with validation and goldens; the result folder gains the reactive tables and the shunt tables.
  • The consumer sends one model to both calls and reads the warning list on the planning side as a routing table of what that target ignored.
  • The derived-Q path (power_factor) is computed by the emitter per snapshot, so a series active set-point yields a series q_set; the two ways to give Q cannot drift apart because only one may be present.
  • Still out of scope: DC sub-networks (buses of carrier DC with lines), tap changers and SVCs that act during the solve, time-varying voltage set-points, and anything pf() does not model. tap_side, the transformer model and line derating stay native-only.
  • ADR-0008 is amended, not rewritten: its dispatch-rejection consequence is superseded by this record.